Floor plans · bedrooms

Bedroom floor plans

Measured bedroom plans you can open, resize and furnish free: a 12 × 12 ft bedroom with a reach-in closet, a primary suite with its bath and walk-in closet, and two bedrooms sharing a Jack and Jill bath. Each one clears the IRC bedroom minimums.

3D cutaway of the 12 by 12 foot bedroom template with a bed, a nightstand, a dresser, windows on two walls and a reach-in closet behind a bifold door.

Bedroom plans

Bedroom sizes

The building code sets a small minimum; what a bedroom needs in practice depends on the bed and on whether it is a child's room, a guest room or the primary bedroom.

Bedroom sizes: IRC minimums (2021 IRC R304, 2024 IRC R312) and typical sizes inside the walls from common practice.
RoomIRC minimumTypical sizePlan
Secondary bedroom70 sq ft, 7 ft each way10 × 10 to 12 × 12 ft12x12 bedroom
Primary bedroom70 sq ft, 7 ft each way12 × 14 ft (queen) to 14 × 16 ft (king)Primary suite
Walk-in closetNone5 × 7 ft one side, 7 × 8 ft both sidesPrimary suite
Reach-in closetNot required24 in deep, 4 to 8 ft wide12x12 bedroom

How much floor a bed needs

US mattress sizes and the floor they need with 30 in at each side and 36 in at the foot. Rule of thumb; frame and headboard not included.
MattressMattress sizeFloor for bed and walkways
Full54 × 75 in9 ft 6 in × 9 ft 3 in
Queen60 × 80 in10 ft × 9 ft 8 in
King76 × 80 in11 ft 4 in × 9 ft 8 in
California king72 × 84 in11 ft × 10 ft

Add a dresser (about 20 in deep plus room to open its drawers), a door swing and a window you can reach, and the 12 × 12 ft room is comfortable with a queen and tight with a king. Master bedroom size works through the clearances.

What to look for in a bedroom plan

  • An escape opening. Every sleeping room needs a window or door to outside with at least 5.7 sq ft of net clear opening (5.0 at a grade-floor opening), 24 in clear high, 20 in clear wide and a sill no higher than 44 in (2021 IRC R310, 2024 IRC R319).
  • A door near a corner. It leaves whole walls for the bed and the dresser; a door in the middle of a wall splits it in two.
  • A wall for the bed. A headboard wall without a window or a door, opposite or beside the entry, with 24 to 36 in to walk past each side.
  • Alarms. Smoke alarms in each sleeping room and outside it (2021 IRC R314), and a CO alarm outside each sleeping area where the house has a fuel-burning appliance or an attached garage that opens into it (2021 IRC R315); see smoke detector placement and CO alarm placement.
  • Storage. The IRC does not require a closet, but buyers expect one; plan 24 in of depth for hanging.

In FloorGen, set a room's Room type to bedroom and the IRC checks flag it as soon as it drops under 70 sq ft or 7 ft across, or has no escape window of the required size. What makes a room a bedroom covers each rule, including the 2024 renumbering.

Questions

What is the minimum size of a bedroom?

Under the IRC, 70 sq ft with no side shorter than 7 ft (2021 IRC R304, R312 in the 2024 edition), a ceiling of at least 7 ft and an emergency escape opening. Some states and cities add their own rules.

What size bedroom do I need for a king bed?

At least about 11 ft 4 in × 9 ft 8 in of floor for the bed and its walkways, and in practice about 14 × 16 ft once you add nightstands, a dresser and a door swing. The primary suite has a 15 × 16 ft bedroom for one.

Does a bedroom need a window?

It needs an emergency escape and rescue opening: a window or a door to outside big enough to climb out of. A basement bedroom with its window below grade also needs a window well; see egress window well requirements.