Lumens calculator
Pick the room, enter its size and the bulbs you plan to use. The calculator multiplies the recommended light level for that room by its floor area, gives the lumens as a range, and lays the bulbs out on a ceiling plan.
Lumens calculator
Recommended: 10–20 fc of general light.
Foot-candles × area counts the lumens on the bulbs' boxes. Shades, dark walls and deep fixtures swallow some of what the bulbs give out, so plan towards the top of the range and put the lights on a dimmer. FloorGen's editor shows the light that reaches desk height, about half the rated lumens, so its figure reads lower.
Lumens needed
1,680–3,360 lm
- Bulbs
- 3–5
- Light level
- 10–20 fc
- Per bulb
- 800 lm
- Floor area
- 168 ft²
Ceiling plan
This room's size, by use
The formula
- Light level: the recommended illuminance for the room, in foot-candles (fc). A living room or bedroom is 10 to 20 fc of general light; a kitchen 30 to 40.
- Floor area: length × width, in ft².
- Lumens = foot-candles × ft². A foot-candle is one lumen per square foot, so the units cancel. In metric, lumens = lux × m², and 1 fc = 10.764 lux.
- Bulbs: lumens ÷ the lumens on the bulb's box, rounded up, for each end of the range.
Sources and assumptions
The light levels are the Illuminating Engineering Society's residential guidance as tabled in Penn State's course EGEE 102, "How much lighting is needed" (read 11 October 2026): living rooms and bedrooms 10–20 fc, kitchen (general) 30–40, bathrooms 20–50, home office and reading 20–50, dining room 30–40, hallways and entries 5–20. The current IES document for homes is ANSI/IES/ALA RP-11-26, which is sold, not published free; laundry rooms are not in the table we could cite, so they are left out. Bulb outputs are the minimum lumens in the ENERGY STAR light bulb purchasing guide (16 March 2020): 450 lm for a 40 W incandescent, 800 for 60 W, 1,100 for 75 W and 1,600 for 100 W. The formula counts the light that should reach the room and ignores what shades, fixtures and dark surfaces absorb, which is why planning towards the top of the range is safer.Worked example
A 14 × 12 ft living room is 168 ft². At 10 to 20 fc it needs 168 × 10 = 1,680 to 168 × 20 = 3,360 lumens. With 800 lm bulbs (the old 60 W), that is 1,680 ÷ 800 = 2.1, so 3 bulbs for the low end, and 3,360 ÷ 800 = 4.2, so 5 bulbs for the high end. Five on a dimmer covers both.
A 12 × 12 ft kitchen is 144 ft² at 30 to 40 fc: 4,320 to 5,760 lumens, 6 to 8 bulbs of 800 lm or 4 to 6 of 1,100 lm, before any task lights under the cabinets. In metric, a 4 × 3 m bedroom is 12 m² at 108 to 215 lux: about 1,292 to 2,583 lumens.
| Room | Size | Light level | Lumens | 800 lm bulbs |
|---|---|---|---|---|
| Bedroom | 10 × 10 ft | 10–20 fc | 1,000–2,000 | 2–3 |
| Bedroom | 12 × 12 ft | 10–20 fc | 1,440–2,880 | 2–4 |
| Living room | 14 × 16 ft | 10–20 fc | 2,240–4,480 | 3–6 |
| Kitchen | 10 × 12 ft | 30–40 fc | 3,600–4,800 | 5–6 |
| Dining room | 12 × 14 ft | 30–40 fc | 5,040–6,720 | 7–9 |
| Bathroom | 5 × 8 ft | 20–50 fc | 800–2,000 | 1–3 |
| Home office | 10 × 10 ft | 20–50 fc | 2,000–5,000 | 3–7 |
| Hallway | 3½ × 12 ft | 5–20 fc | 210–840 | 1–2 |
Layers of light
- General light is what this calculator sizes: ceiling fixtures, recessed lights or a central pendant that light the whole floor.
- Task light goes where the work is: under-cabinet strips over a counter, a vanity light at the mirror, a desk lamp. Penn State's table gives 50 to 100 fc at a kitchen's stove and sink, well above the room's general level.
- Dimmers let one layout serve both ends of a range, bright for cleaning and low in the evening. Check that the bulbs are sold as dimmable.
- Even spacing matters as much as the total: a grid of smaller lights gives fewer shadows than one bright fixture in the middle. The ceiling plan above spaces them evenly; the recessed lighting calculator sets the spacing and the distance from the walls from the ceiling height.
Plan the lights on the plan
In a FloorGen plan every room already has its area. Open the room from the calculator, place the fixtures where the ceiling plan shows them, and add the switches by the doors.
The editor's lighting view will read lower than this calculator. The calculator counts the lumens on the bulbs' boxes; the editor counts the light that reaches desk height, about half of it once the walls, the ceiling and the bulbs' dirt and age take their share, and gives each room its own target in lux. The calculator shows that figure too, under the result.
Open a 12 × 14 ft L-shaped kitchen Opens an L-shaped kitchen with its range, sink and fridge in the FloorGen studio, free and without an account. At 30 to 40 fc, its 168 ft² wants 5,040 to 6,720 lumens of general light.
Questions
How many lumens do I need for a 12 × 12 bedroom?
How many lumens per square foot for a kitchen?
How many lumens is a 60 watt bulb?
What is the difference between lux and foot-candles?
Does ceiling height change the lumens?
Plan the room before you buy the bulbs.
Draw without an account or a card. A free account adds exports, cloud sync and FloorGen AI. Your plans save in this browser; sign in later to keep them in the cloud.