BTU calculator

Enter the room's size, how sunny it is, how many people use it and whether it is a kitchen. The calculator reads the room air conditioner size off the ENERGY STAR sizing chart and applies its adjustments, in BTU per hour, tons and kilowatts.

BTU calculator

Room size
ft
in
ft
in
Sun

Each regular occupant past two adds 600 BTU/hr.

The chart assumes an 8 ft (2.4 m) ceiling, as ENERGY STAR does. A taller room, a top floor under a hot roof or a poorly insulated room may need more.

Air conditioner size

7,200 BTU/hr

168 ft² · 2.11 kW of cooling
Tons
0.6
Chart row
150–250 ft²
Size up
8k
Kilowatts
2.11 kW

The room from above

to scale
168 ft²

Where it sits among room AC sizes

BTU/hr
5k8k12k18k24k34k7.2k

Where the BTUs come from

BTU/hr
02,0004,0006,0008,0006,000Chart+600Sun+600People0Kitchen7,200Total
Open as a floor plan

The method

  1. Floor area: length × width, in square feet (the chart is in ft²; a metric room is converted, 1 m² = 10.764 ft²).
  2. Read the chart: ENERGY STAR gives a capacity for each band of area, from 5,000 BTU/hr for 100 up to 150 ft² to 34,000 BTU/hr for 2,000 up to 2,500 ft².
  3. Sun: take off 10% for a heavily shaded room, add 10% for a very sunny one.
  4. People: add 600 BTU/hr for each person past two who regularly uses the room.
  5. Kitchen: add 4,000 BTU/hr if the unit cools a kitchen.
  6. Pick a unit: the next size up on the chart. Tons are BTU/hr ÷ 12,000; kilowatts are BTU/hr ÷ 3,412.

Sources and assumptions

The chart and the four adjustments are from ENERGY STAR's room air conditioner page ("Properly sized room air conditioners", read 11 October 2026). ENERGY STAR notes that the capacities assume an 8 ft ceiling; a taller room, a room under a hot roof or a poorly insulated one may need more. ENERGY STAR lists the adjustments without an order; this calculator applies the sun percentage to the chart's figure, then adds people and the kitchen. One kilowatt-hour is 3,412 Btu (U.S. EIA, read 11 October 2026), so 1 kW of cooling is 3,412 BTU/hr. For central air or a whole house, a contractor's load calculation (ACCA Manual J) replaces this chart.
Free · draw without an accountCarry on in a floor planDraw the rooms to scale in the FloorGen editor and keep every size in one plan.
Open as a floor plan

Worked example

A 14 × 12 ft bedroom is 168 ft², in the chart's 150 up to 250 ft² band: 6,000 BTU/hr. It gets the afternoon sun, so add 10% (600). Three people sleep there, one past two, so add 600 more: 7,200 BTU/hr, 0.6 tons or 2.11 kW. The next size on the chart is an 8,000 BTU/hr unit. The same room as a kitchen would need 11,200 BTU/hr, a 12,000 BTU/hr unit.

In metric, a 4 × 3.5 m room is 14 m², or 150.7 ft²: just inside the 150 ft² band, so 6,000 BTU/hr (1.76 kW) before any adjustment.

Air conditioner size for common rooms: two people, no kitchen, 8 ft ceiling (worked with the calculator)
RoomAreaNormal sunVery sunnyUnit for a sunny room
10 × 10 ft100 ft²5,000 BTU/hr5,500 BTU/hr6,000
10 × 12 ft120 ft²5,000 BTU/hr5,500 BTU/hr6,000
12 × 12 ft144 ft²5,000 BTU/hr5,500 BTU/hr6,000
12 × 14 ft168 ft²6,000 BTU/hr6,600 BTU/hr7,000
14 × 16 ft224 ft²6,000 BTU/hr6,600 BTU/hr7,000
16 × 20 ft320 ft²8,000 BTU/hr8,800 BTU/hr9,000
20 × 20 ft400 ft²10,000 BTU/hr11,000 BTU/hr12,000
20 × 25 ft500 ft²12,000 BTU/hr13,200 BTU/hr14,000
24 × 25 ft600 ft²14,000 BTU/hr15,400 BTU/hr18,000

Why bigger is not better

  • An oversized unit leaves the room clammy: in ENERGY STAR's words, it "will cool the room before it has a chance to remove the humidity", and it costs more to buy and run.
  • Undersized is the other failure: on the hottest afternoons the unit runs flat out and never reaches the set temperature. If you sit between two sizes, the sun and the people decide it.
  • Measure the room you will actually cool. If a doorway or an arch opens onto another room with no door, count both rooms' floor area.
  • Placement matters too: keep lamps and TVs away from the unit's thermostat (their heat makes it run longer), and in a corner choose a unit that can throw its air the right way.

Every room in a plan

A floor plan gives you every room's exact area at once. Draw the house in FloorGen, read each room's area off the plan, and size a unit for each room that needs one. How to measure a room covers getting the dimensions right.

Open a 12 × 12 ft bedroom Opens a furnished 12 × 12 ft bedroom in the FloorGen studio, free and without an account. Change its size and the area updates; 144 ft² is a 5,000 BTU/hr room on the ENERGY STAR chart.

Questions

What size air conditioner do I need for a 12 × 12 room?
A 12 × 12 ft room is 144 ft², which the ENERGY STAR chart puts at 5,000 BTU/hr. Add 10% if it is very sunny (5,500, so a 6,000 BTU/hr unit) and 600 BTU/hr for each regular occupant past two.
How many square feet does a 10,000 BTU air conditioner cool?
On the ENERGY STAR chart, 10,000 BTU/hr is the size for 400 up to 450 ft², with an 8 ft ceiling and normal sun. In a very sunny room it covers less.
How many BTU is a ton of air conditioning?
12,000 BTU per hour. A 6,000 BTU/hr window unit is half a ton; a 24,000 BTU/hr unit is two tons.
How do I convert BTU/hr to kilowatts?
Divide by 3,412. A 12,000 BTU/hr unit is about 3.5 kW of cooling. This is cooling output, not the electricity the unit draws, which is much less.
Do high ceilings change the size?
They can. ENERGY STAR's chart assumes an 8 ft ceiling; a room with a much taller ceiling has more air to cool, so lean towards the next size up and check the manufacturer's guidance.