Standard Window Sizes: Size Codes, Rough Openings and Egress

Standard window sizes in US homes: double-hung 24 to 48 in wide and 36 to 72 in tall, size codes like 3050, rough openings, egress, safety glass and a plan.

Standard window sizes in US homes run from about 24 to 48 in wide and 36 to 72 in tall for double-hung windows, the most common type, and makers name them with a four-digit code: 3050 means 3 ft 0 in wide by 5 ft 0 in tall. The code is a nominal size. The real unit is usually a little different, and the rough opening in the wall is about ½ in bigger than the unit, so always size the opening from the maker's chart. Bedroom windows also have to meet the escape-opening rule: at least 5.7 ft² clear, 24 in high, 20 in wide, and no more than 44 in off the floor.

Below are the common sizes, how to read a size code, rough openings, the code rules that limit size and placement (egress, safety glass, fall protection, daylight), and the windows of a real three-bedroom house plan. For doors, see standard door sizes.

Common window sizes

Typical size ranges from home-improvement guides (Angi, HomeGuide and others). Each maker's chart differs; check the line you buy.
Window typeCommon widthsCommon heightsWhere it is used
Double-hung or single-hung24 to 48 in36 to 72 inBedrooms, living rooms, most of the house
Slider (gliding)Varies by maker; usually wider than tallVaries by makerBasements, over counters, low walls
CasementVaries by maker; usually taller than wideVaries by makerOver sinks, egress windows, modern houses
Picture (fixed)Often made to orderOften made to orderViews; does not open, so no ventilation or egress

Guides agree on the double-hung range but not on every step inside it; some list widths in 4 in steps (24, 28, 32 in and so on), others in larger ones. Casement and slider sizes vary more between makers, so take them from the chart of the line you choose.

How to read a window size code

A four-digit code gives the width in feet and inches, then the height in feet and inches: 2030 is 2 ft 0 in × 3 ft 0 in, 3050 is 3 ft 0 in × 5 ft 0 in, 2852 is 2 ft 8 in × 5 ft 2 in (32 × 62 in). Width always comes first. Some makers code in inches instead, and the code can refer to either the unit or the rough opening, depending on the maker.

The code is a name, not a measurement. In Andersen's 400 Series tilt-wash chart, for example, the unit sold as TW3052 measures 3 ft 1⅝ in × 5 ft 4⅞ in, and the chart lists its minimum rough opening as the unit size plus ½ in each way. Order from the chart, not the code.

Rough openings and window height

  • Rough opening: the framed hole, usually about ½ in wider and taller than the unit, which leaves room to shim it plumb and seal it. The maker's chart gives the exact figure for each size.
  • Head height: many builders line the tops of windows up with the tops of the doors, often 6 ft 8 in or a little higher on 8 ft walls. That is common practice, not code, but a façade looks calmer when heads line up.
  • Sill height: set by the room. Over a kitchen counter the sill has to clear the 36 in counter and backsplash; in a bedroom it must be 44 in or lower for egress; a low sill on an upper floor brings in the fall protection rule below.

Code rules that limit window size

Window rules in the 2021 International Residential Code (section numbers in the 2024 edition in brackets). Most US jurisdictions adopt the IRC with amendments.
RuleWhat it requiresSection
Emergency escape openingEvery sleeping room: at least 5.7 ft² clear (5.0 ft² at grade), 24 in clear high, 20 in clear wide, sill no more than 44 in above the floorR310 [R319]
Light and ventilationGlazing of at least 8% of the room's floor area, and openable area of at least 4%, unless lighting and mechanical ventilation are provided insteadR303.1
Safety glass by a doorGlazing within 24 in of a door edge whose bottom is less than 60 in above the floorR308.4.2 [R324]
Safety glass in large panesA pane over 9 ft² with its bottom less than 18 in and top more than 36 in above the floor, near a walking surfaceR308.4.3 [R324]
Safety glass near a tub or showerGlazing within 60 in of the water's edge whose bottom is less than 60 in above the standing surfaceR308.4.5 [R324]
Window fall protectionWhere the sill is less than 24 in above the floor and the opening more than 72 in above the ground outside, a limit on the opening or a fall prevention deviceR312.2.1 [R321]

The egress rule is about the clear opening, not the unit size, and the window type changes it a lot. A casement opens almost its full size; a double-hung opens only one sash, about half its height; a slider half its width. A double-hung bedroom window has to be roughly twice as tall as a casement to give the same clear height, which is why egress windows in basements are so often casements or sliders. Our guides to egress window requirements and legal bedroom requirements have the details.

The windows in a three-bedroom ranch

FloorGen's 3-bed ranch template, a 70 × 36 ft house with a two-car garage, uses five window widths. All are double-hung, 4 ft 3 in (130 cm) tall with the sill at about 35½ in (90 cm), except the two small bathroom windows, which are about 24 × 24 in and set high:

Windows in the 3-bed ranch template, as drawn (FloorGen measurements, rounded to the inch).
RoomWindows (width × height)
Living roomTwo 60 × 51 in
Dining roomOne 60 × 51 in
Primary bedroomOne 60 × 51 in
KitchenOne 48 × 51 in
Bedrooms 2 and 3One 48 × 51 in each, plus a 36 × 51 in on the east wall of bedroom 3
Laundry and garageOne 30 × 51 in and one 36 × 51 in
Primary and hall bathsSmall 24 × 24 in windows, sill about 55 in
Floor plan of a three-bedroom ranch with a two-car garage, entry, living room, kitchen, dining room, laundry, hall bath and a primary suite with walk-in closet
The 3-bed ranch, exported from FloorGen. Windows show as breaks in the outside walls.

Every bedroom passes FloorGen's escape-opening check: a 48 × 51 in double-hung opens about half its height, roughly 48 × 25½ in or 8½ ft², well over the 5.7 ft² minimum, with a 35½ in sill. Change the same window to a casement and the check counts nearly the whole unit, about 17 ft². The daylight rule is closer: the primary bedroom has 266.1 ft² of floor and one 60 × 51 in window, about 21¼ ft² as a unit, right at the 8% line (21.3 ft²), and the glass itself is smaller than the unit, so a real design would enlarge it or add a second window.

3D cutaway of the ranch house showing the garage with two cars, the living room, the bedrooms and the bathrooms
The ranch in 3D.

Windows in FloorGen

Each window has a Window type (casement, double-hung, slider, awning, picture or tilt-and-turn), a width, a height and a Sill height. Under the IRC profile, FloorGen checks every bedroom for an escape opening, estimating the clear opening from the type, and flags a habitable room with no window at all. In the elevations, Façade notes point out windows whose heads or sills do not line up. It does not check the 8% glazing ratio, safety glass or fall protection, and its clear opening is an estimate from the overall size, so confirm the net clear opening from the maker's egress data. More on drawing them in how to draw a floor plan.